Long-term feasibility of the new sutureless excimer laser-assisted non-occlusive anastomosis clip in a pig model
BACKGROUND: High flow bypass surgery can be a last resort procedure for patients suffering from complex neurovascular pathology. Temporary occlusion of a recipient artery in these patients could result in debilitating neurological deficits. We developed a sutureless, mechanical anastomotic connectio...