Reliability of mecA in Predicting Phenotypic Susceptibilities of Coagulase-Negative Staphylococci and Staphylococcus aureus

The mecA gene is commonly used to identify resistance in Staphylococcus aureus, but historically is not used for coagulase-negative staphylococci (CoNS). Analysis of 412 staphylococcal blood cultures (2014–2018) revealed that the absence of mecA had high concordance (100%) with oxacillin susceptibil...

Descripció completa

Guardat en:
Dades bibliogràfiques
Publicat a:Open Forum Infect Dis
Autors principals: Williams, Manon C, Dominguez, Samuel R, Prinzi, Andrea, Lee, Kayla, Parker, Sarah K
Format: Artigo
Idioma:Inglês
Publicat: Oxford University Press 2020
Matèries:
Accés en línia:https://ncbi.nlm.nih.gov/pmc/articles/PMC7759207/
https://ncbi.nlm.nih.gov/pubmed/33409329
https://ncbi.nlm.nih.govhttp://dx.doi.org/10.1093/ofid/ofaa553