Successful percutaneous removal of dislodged ring-marker of optical coherence tomography catheter using the twisted wire technique with a guide-extension catheter: A case report

An 81-year-old male with diabetes and hypertension was admitted to our hospital due to chest pain on exertion. Coronary angiography revealed a severe stenosis at the middle of right coronary artery (RCA). We performed percutaneous coronary intervention under the guidance of optical coherence tomogra...