Real-time CGM Is Superior to Flash Glucose Monitoring for Glucose Control in Type 1 Diabetes: The CORRIDA Randomized Controlled Trial

OBJECTIVE: The aim of this trial was to compare the efficacy of real-time and intermittently scanned continuous glucose monitoring (rtCGM and isCGM, respectively) in maintaining optimal glycemic control. RESEARCH DESIGN AND METHODS: In this randomized study, adults with type 1 diabetes (T1D) and nor...