Massive Air Embolism during off-pump CABG: A Case Report
Off-pump coronary artery bypass grafting (OPCAB), although devoid of the morbidity associated with cardiopulmonary bypass (CPB), has its own technical difficulties. Achieving optimum tissue stabilization on a beating heart along with hemodynamic fragility due to extreme positioning also complicates...