Načítá se...

3PC-015 Media-fill simulation tests of infusion bags prepared in series by the compounding robot apotecachemo

BACKGROUND: The implementation of dose-banding in centralised cytotoxic preparation units allows the preparation of standardised doses in series. Based on this concept, dose-banded ready-to-administer ganciclovir infusion bags are prepared in series in the Pharmacy Department by using the APOTECAche...

Celý popis

Uloženo v:
Podrobná bibliografie
Vydáno v:Eur J Hosp Pharm
Hlavní autoři: Federici, M, Krämer, I
Médium: Artigo
Jazyk:Inglês
Vydáno: BMJ Group 2018
Témata:
On-line přístup:https://ncbi.nlm.nih.gov/pmc/articles/PMC7535481/
https://ncbi.nlm.nih.govhttp://dx.doi.org/10.1136/ejhpharm-2018-eahpconf.67
Tagy: Přidat tag
Žádné tagy, Buďte první, kdo otaguje tento záznam!