Caricamento...
Use of preoperative cone-beam computed tomography to aid in establishment of endodontic working length: A systematic review and meta-analysis
PURPOSE: This study was performed to assess the accuracy of preoperative cone-beam computed tomography (CBCT), when justified for other reasons, in locating the apical foramen and establishing the working length. MATERIALS AND METHODS: Six electronic databases were searched for studies on this subje...
Salvato in:
| Pubblicato in: | Imaging Sci Dent |
|---|---|
| Autori principali: | , , , |
| Natura: | Artigo |
| Lingua: | Inglês |
| Pubblicazione: |
Korean Academy of Oral and Maxillofacial Radiology
2020
|
| Soggetti: | |
| Accesso online: | https://ncbi.nlm.nih.gov/pmc/articles/PMC7506090/ https://ncbi.nlm.nih.gov/pubmed/33005575 https://ncbi.nlm.nih.govhttp://dx.doi.org/10.5624/isd.2020.50.3.183 |