A carregar...

Effect of Different Implant Designs on Strain and Stress Distribution under Non-Axial Loading: A Three-Dimensional Finite Element Analysis

Implant design evolved alongside the development of implant therapy. The purpose of this finite element analysis (FEA) study was to analyze the influence of different implant designs on the stress and strain distribution to the implants and surrounding bone. Three implant designs with the same lengt...

ver descrição completa

Na minha lista:
Detalhes bibliográficos
Publicado no:Int J Environ Res Public Health
Main Authors: Oliveira, Hélder, Brizuela Velasco, Aritza, Ríos-Santos, José-Vicente, Sánchez Lasheras, Fernando, Lemos, Bernardo Ferreira, Gil, Francisco Javier, Carvalho, Alexandrine, Herrero-Climent, Mariano
Formato: Artigo
Idioma:Inglês
Publicado em: MDPI 2020
Assuntos:
Acesso em linha:https://ncbi.nlm.nih.gov/pmc/articles/PMC7370002/
https://ncbi.nlm.nih.gov/pubmed/32630294
https://ncbi.nlm.nih.govhttp://dx.doi.org/10.3390/ijerph17134738
Tags: Adicionar Tag
Sem tags, seja o primeiro a adicionar uma tag!