A carregar...

Joint optimization of collimator and reconstruction parameters in x-ray fluorescence computed tomography using analytical point spread function and model observer

OBJECTIVE: To jointly optimize collimator design and image reconstruction algorithm in X-ray Fluorescence Computed Tomography (XFCT) for imaging low concentrations of high atomic number (Z) elements in small animal models. METHODS: Single pinhole (SPH) collimator and three types of multi-pinhole (MP...

ver descrição completa

Na minha lista:
Detalhes bibliográficos
Publicado no:IEEE Trans Biomed Eng
Main Authors: Tseng, Hsin Wu, Vedantham, Srinivasan, Cho, Sang Hyun, Karellas, Andrew
Formato: Artigo
Idioma:Inglês
Publicado em: 2019
Assuntos:
Acesso em linha:https://ncbi.nlm.nih.gov/pmc/articles/PMC7326652/
https://ncbi.nlm.nih.gov/pubmed/31899411
https://ncbi.nlm.nih.govhttp://dx.doi.org/10.1109/TBME.2019.2963040
Tags: Adicionar Tag