Case report of successful low-dose, ultra-slow infusion thrombolysis of prosthetic mitral valve thrombosis in a high risk patient after redo-mitral valve replacement
BACKGROUND: An increase in transvalvular pressure gradient of prosthetic valve should always raise suspicion for obstructive valve thrombosis. A multimodality diagnostic approach including transthoracic echocardiography, transoesophageal echocardiography (TOE), cinefluoroscopy, or computed tomograph...
Na minha lista:
| Publicado no: | Eur Heart J Case Rep |
|---|---|
| Main Authors: | , , |
| Formato: | Artigo |
| Idioma: | Inglês |
| Publicado em: |
Oxford University Press
2020
|
| Assuntos: | |
| Acesso em linha: | https://ncbi.nlm.nih.gov/pmc/articles/PMC7319841/ https://ncbi.nlm.nih.gov/pubmed/32617496 https://ncbi.nlm.nih.govhttp://dx.doi.org/10.1093/ehjcr/ytaa053 |