Wird geladen...

Comparison of SARS‐CoV‐2 detection from nasopharyngeal swab samples by the Roche cobas 6800 SARS‐CoV‐2 test and a laboratory‐developed real‐time RT‐PCR test

The urgent need to implement and rapidly expand testing for severe acute respiratory syndrome coronavirus‐2 (SARS‐CoV‐2) infection has led to the development of multiple assays. How these tests perform relative to one another is poorly understood. We evaluated the concordance between the Roche Diagn...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:J Med Virol
Hauptverfasser: Pujadas, Elisabet, Ibeh, Nnaemeka, Hernandez, Matthew M., Waluszko, Aneta, Sidorenko, Tatyana, Flores, Vanessa, Shiffrin, Biana, Chiu, Numthip, Young‐Francois, Alicia, Nowak, Michael D., Paniz‐Mondolfi, Alberto E., Sordillo, Emilia M., Cordon‐Cardo, Carlos, Houldsworth, Jane, Gitman, Melissa R.
Format: Artigo
Sprache:Inglês
Veröffentlicht: John Wiley and Sons Inc. 2020
Schlagworte:
Online Zugang:https://ncbi.nlm.nih.gov/pmc/articles/PMC7267546/
https://ncbi.nlm.nih.gov/pubmed/32383179
https://ncbi.nlm.nih.govhttp://dx.doi.org/10.1002/jmv.25988
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!