A carregar...
Small bowel perforation caused by applicator implantation in high-dose-rate interstitial brachytherapy for recurrent pelvic tumor: a case report
High-dose-rate interstitial brachytherapy (HDR-ISBT) is widely used for the treatment of pelvic tumors. However, there are a few reports on complications of applicator implantation in HDR-ISBT. We describe a case of small bowel perforation caused by applicator implantation in an 82-year-old male pat...