Everolimus-Eluting Biodegradable Abluminal Coating Stent versus Durable Conformal Coating Stent: Termination of the Inflammatory Response Associated with Neointimal Healing in a Porcine Coronary Model
OBJECTIVES: We evaluated the effect of the different carrier systems on early vascular response through histological analysis and scanning electron microscopy using a porcine model. BACKGROUND: Although Synergy™ and Promus PREMIER™ share an identical stent material and drug elution (everolimus), the...