A New Capacitance Sensor for Measuring the Void Fraction of Two-Phase Flow Through Tube Bundles

Evaluating the two-phase flow parameters across tube bundles is crucial to the analysis of vibration excitation mechanisms. These parameters include the temporal and local variation of void fraction and phase redistribution. Understanding these two-phase parameters is essential to evaluating the sta...

ver descrição completa

Na minha lista:
Detalhes bibliográficos
Publicado no:Sensors (Basel)
Main Authors: Ahmed, Wael, Fatayerji, Adib, Elsaftawy, Ahmed, Hassan, Marwan, Weaver, David, Riznic, Jovica