The frequency of reduction loss after arthroscopic fixation of acute acromioclavicular dislocations using a double-button device, and its effect on clinical and radiological results

BACKGROUND: The aim of this study was to investigate the effect of reduction loss of more than 3 mm on clinical and radiological results after at least 2 years of follow-up after arthroscopic fixation of acute acromioclavicular joint dislocations using a double-button device. METHODS: Thirty-six pat...