Retention of CAD-CAM resin composite crowns following different bonding protocols
PURPOSE: To evaluate the effect of different surface treatments and primers with a CAD-CAM resin composite block on its crown retention. METHODS: 120 human molars were prepared with a 24° total convergence angle, 1.5 mm height, and axial walls in dentin. Surface area was measured by digital microsco...
Uloženo v:
Vydáno v: | Am J Dent |
---|---|
Hlavní autoři: | , , , , , , |
Médium: | Artigo |
Jazyk: | Inglês |
Vydáno: |
2018
|
Témata: | |
On-line přístup: | https://ncbi.nlm.nih.gov/pmc/articles/PMC7135944/ https://ncbi.nlm.nih.gov/pubmed/29630794 |
Tagy: |
Přidat tag
Žádné tagy, Buďte první, kdo otaguje tento záznam!
|