Tissue Response of a Small Saccular Aneurysm after Incomplete Occlusion with a Guglielmi Detachable Coil
Summary: A 49-year-old woman had a small saccular aneurysm that was incompletely occluded with a Guglielmi detachable coil (GDC). She died from rupture of another aneurysm 42 days after the treatment. Autopsy for the embolized aneurysm revealed no neoendothelium at the aneurysmal neck, but an organi...