טוען...
Fiber-Optic Multipoint Sensor System with Low Drift for the Long-Term Monitoring of High-Temperature Distributions in Chemical Reactors
A low-drift fiber-optic sensor system, consisting of 24 regenerated fiber Bragg gratings (RFBG), equally distributed over a length of 2.3 m, is presented here. The sensor system can monitor spatially extended temperature profiles with a time resolution of 1 Hz at temperatures of up to 500 °C. The sy...
שמור ב:
| הוצא לאור ב: | Sensors (Basel) |
|---|---|
| Main Authors: | , , , , |
| פורמט: | Artigo |
| שפה: | Inglês |
| יצא לאור: |
MDPI
2019
|
| נושאים: | |
| גישה מקוונת: | https://ncbi.nlm.nih.gov/pmc/articles/PMC6960593/ https://ncbi.nlm.nih.gov/pubmed/31842298 https://ncbi.nlm.nih.govhttp://dx.doi.org/10.3390/s19245476 |
| תגים: |
הוספת תג
אין תגיות, היה/י הראשונ/ה לתייג את הרשומה!
|