Kilohertz high-frequency alternating current blocks nerve conduction without causing nerve damage in rats
BACKGROUND: In recent years, 2–50 kHz high-frequency alternating current has been shown to block nerve conduction mostly based on simulation models or experiments in vitro. This study aimed to assess the nerve block effects and related parameters of kilohertz alternating current in a rat model. METH...