Loading...

Considerations regarding Maximal Lactate Steady State determination before redefining the gold‐standard

We have read with interest the review written by Jones et al. (2019) published in a recent volume‐issue (volume 7, issue 5) of the journal. Criticisms regarding maximal lactate steady state intensity determination are to some extent correct and well‐justified. There are some aspects, however, that s...

Fuld beskrivelse

Na minha lista:
Bibliografiske detaljer
Udgivet i:Physiol Rep
Main Authors: Garcia‐Tabar, Ibai, Gorostiaga, Esteban M.
Format: Artigo
Sprog:Inglês
Udgivet: John Wiley and Sons Inc. 2019
Fag:
Online adgang:https://ncbi.nlm.nih.gov/pmc/articles/PMC6874780/
https://ncbi.nlm.nih.gov/pubmed/31758638
https://ncbi.nlm.nih.govhttp://dx.doi.org/10.14814/phy2.14293
Tags: Tilføj Tag
Ingen Tags, Vær først til at tagge denne postø!