Human Errors and Adverse Hemodynamic Events Related to “Push Dose Pressors” in the Emergency Department
BACKGROUND: Though the use of small bolus doses of vasopressors, termed “push dose pressors,” has become common in emergency medicine, data examining this practice are scant. Push dose pressors frequently involve bedside dilution, which may result in errors and adverse events. The objective of this...