Aorto–Esophageal Fistula Caused by Distal Stent Graft-Induced New Entry after Frozen Elephant Trunk Technique for Chronic Aortic Dissection

We present a case of aorto–esophageal fistula (AEF) caused by distal stent graft-induced new entry (dSINE) after the frozen elephant trunk (FET) technique for chronic aortic dissection. We propose that the combination of the spring-back force and the radial force of the FET may play a role in the oc...