Carregant...

A Fully-Differential Switched-Capacitor Dual-Slope Capacitance-To-Digital Converter (CDC) for a Capacitive Pressure Sensor

This article focuses on a proposed Switched-Capacitor Dual-Slope based CDC. Special attention is paid to the measurement setup using a real pressure sensor. Performance scaling potential as well as dead zones are pointed out and discussed. In depth knowledge of the physical sensor behavior is key to...

Descripció completa

Guardat en:
Dades bibliogràfiques
Publicat a:Sensors (Basel)
Autors principals: Rogi, Christopher, Buffa, Cesare, De Milleri, Niccolo, Gaggl, Richard, Prefasi, Enrique
Format: Artigo
Idioma:Inglês
Publicat: MDPI 2019
Matèries:
Accés en línia:https://ncbi.nlm.nih.gov/pmc/articles/PMC6749500/
https://ncbi.nlm.nih.gov/pubmed/31450829
https://ncbi.nlm.nih.govhttp://dx.doi.org/10.3390/s19173673