Humeral Shaft Non-union in a Patient with Osteogenesis Imperfecta Treated with Mandible Locking Plate Fixation: A Case Report

INTRODUCTION: Osteogenesis imperfecta (OI) is a heritable disorder of connective tissue. Due to poor bone quality, patients with OI develop bone fracture and subsequent non-union at high rates. We report the rare case of humeral shaft non-union successfully treated by a locking plate used formandibu...

全面介紹

Na minha lista:
書目詳細資料
發表在:J Orthop Case Rep
Main Authors: Sano, Shohei, Oe, Keisuke, Fukui, Tomoaki, Hayashi, Shinya, Kuroda, Ryosuke, Niikura, Takahiro
格式: Artigo
語言:Inglês
出版: Indian Orthopaedic Research Group 2019
主題:
在線閱讀:https://ncbi.nlm.nih.gov/pmc/articles/PMC6742884/
https://ncbi.nlm.nih.gov/pubmed/31559219
https://ncbi.nlm.nih.govhttp://dx.doi.org/10.13107/jocr.2250-0685.1400
標簽: 添加標簽
沒有標簽, 成為第一個標記此記錄!