Anterior Leaflet Laceration to Prevent Ventricular Outflow Tract Obstruction During Transcatheter Mitral Valve Replacement

BACKGROUND: Left ventricular outflow tract (LVOT) obstruction is a leading cause of mortality and exclusion from transcatheter mitral valve replacement (TMVR). Intentional laceration of the anterior mitral valve leaflet to prevent LVOT obstruction (LAMPOON) is a transcatheter mimic of surgical chord...

Descripció completa

Guardat en:
Dades bibliogràfiques
Publicat a:J Am Coll Cardiol
Autors principals: Khan, Jaffar M., Babaliaros, Vasilis C., Greenbaum, Adam B., Foerst, Jason R., Yazdani, Shahram, McCabe, James M., Paone, Gaetano, Eng, Marvin H., Leshnower, Bradley G., Gleason, Patrick T., Chen, Marcus Y., Wang, Dee Dee, Tian, Xin, Stine, Annette M., Rogers, Toby, Lederman, Robert J.