High‐Field Detection of Biomarkers with Fast Field‐Cycling MRI: The Example of Zinc Sensing

Many smart magnetic resonance imaging (MRI) probes provide response to a biomarker based on modulation of their rotational correlation time. The magnitude of such MRI signal changes is highly dependent on the magnetic field and the response decreases dramatically at high fields (>2 T). To overcom...

Descripció completa

Guardat en:
Dades bibliogràfiques
Publicat a:Chemistry
Autors principals: Bödenler, Markus, Malikidogo, Kyangwi P., Morfin, Jean‐François, Aigner, Christoph Stefan, Tóth, Éva, Bonnet, Célia S., Scharfetter, Hermann
Format: Artigo
Idioma:Inglês
Publicat: John Wiley and Sons Inc. 2019
Matèries:
Accés en línia:https://ncbi.nlm.nih.gov/pmc/articles/PMC6618089/
https://ncbi.nlm.nih.gov/pubmed/30990914
https://ncbi.nlm.nih.govhttp://dx.doi.org/10.1002/chem.201901157