Goal-Driven Beam Setting Optimization for Whole-Breast Radiation Therapy
PURPOSE: To develop an automated optimization program to generate optimal beam settings for whole-breast radiation therapy driven by clinically oriented goals. MATERIALS AND METHODS: Forty patients were retrospectively included in this study. Each patient’s planning images, contoured structures of p...