Numerical simulation modeling of the irreversible electroporation treatment zone for focal therapy of prostate cancer, correlation with whole-mount pathology and T2-weighted MRI sequences

BACKGROUND: At present, it is not possible to predict the ablation zone volume following irreversible electroporation (IRE) for prostate cancer (PCa). This study aimed to determine the necessary electrical field threshold to ablate human prostate tissue in vivo with IRE. METHODS: In this prospective...

ver descrição completa

Na minha lista:
Detalhes bibliográficos
Publicado no:Ther Adv Urol
Main Authors: Scheltema, Matthijs J., O’Brien, Tim J., van den Bos, Willemien, de Bruin, Daniel M., Davalos, Rafael V., van den Geld, Cees W.M., Laguna, Maria P., Neal, Robert E., Varkarakis, Ioannis M., Skolarikos, Andreas, Stricker, Phillip D., de Reijke, Theo. M., Arena, Christopher B., de la Rosette, Jean