Aortic Rupture during Endovascular Repair of a Postoperative Coarctation Pseudoaneurysm in an Adult: Emergency Lifesaving Stent Graft Implantation

We present a case with aortic rupture during an operation of thoracic endovascular aortic repair of an anastomotic pseudoaneurysm. This happened after the use of a low-pressure remodeling balloon inside the covered part of the deployed endografts. It was successfully treated with a second more centr...