Chargement en cours...

A paradigmatic case of haemolysis and pseudohyperkalemia in blood gas analysis

A 51-year old male patient was admitted to the hospital with acute dyspnea and history of chronic asthma. Venous blood was drawn into a 3.0 mL heparinized syringe and delivered to the laboratory for blood gas analysis (GEM Premier 4000, Instrumentation Laboratory), which revealed high potassium valu...

Description complète

Enregistré dans:
Détails bibliographiques
Publié dans:Biochem Med (Zagreb)
Auteurs principaux: Salvagno, Gian Luca, Demonte, Davide, Lippi, Giuseppe
Format: Artigo
Langue:Inglês
Publié: Croatian Society of Medical Biochemistry and Laboratory Medicine 2019
Sujets:
Accès en ligne:https://ncbi.nlm.nih.gov/pmc/articles/PMC6366946/
https://ncbi.nlm.nih.gov/pubmed/30799980
https://ncbi.nlm.nih.govhttp://dx.doi.org/10.11613/BM.2019.011003
Tags: Ajouter un tag
Pas de tags, Soyez le premier à ajouter un tag!