Quantitative Zonal Differentiation of Articular Cartilage by Microscopic Magnetic Resonance Imaging, Polarized Light Microscopy, and Fourier-Transform Infrared Imaging
This study aimed to synchronize the zonal differentiation of the full-thickness articular cartilage by three micro-imaging techniques, namely microscopic magnetic resonance imaging (μMRI), polarized light microscopy (PLM), and Fourier-transform infrared imaging (FTIRI). Eighteen cartilage-bone block...