Wird geladen...

A Case Report of the Successful Conversion of One of the Longest Standing KineSpring Joint Unloading Systems

INTRODUCTION: We present the case of a successful conversion of a KineSpring joint unloading system to a total knee replacement. This is, to the best of our knowledge, the so far longest surviving implant in Germany that has been successfully converted. CASE REPORT: The patient is a 75-year-old woma...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:J Orthop Case Rep
Hauptverfasser: Maier, Gerrit Steffen, Maus, Uwe, Horas, Konstantin, Hartmann, Frank, Lazovic, Djordje
Format: Artigo
Sprache:Inglês
Veröffentlicht: Indian Orthopaedic Research Group 2018