A carregar...

Repeat stent implementation for recanalization of the proximal right coronary artery: a case report

BACKGROUND: A stent in a false lumen is a common cause of stent occlusion after coronary percutaneous coronary artery intervention therapy, particularly in the culprit lesion of acute myocardial infarction. Here, we present an unusual case of successful recanalization of the proximal right coronary...

ver descrição completa

Na minha lista:
Detalhes bibliográficos
Publicado no:J Med Case Rep
Main Authors: Wang, Yabin, Gao, Lei, Zhang, Ming, Chen, Yundai, Cao, Feng
Formato: Artigo
Idioma:Inglês
Publicado em: BioMed Central 2018
Assuntos:
Acesso em linha:https://ncbi.nlm.nih.gov/pmc/articles/PMC6311301/
https://ncbi.nlm.nih.gov/pubmed/30594255
https://ncbi.nlm.nih.govhttp://dx.doi.org/10.1186/s13256-018-1897-3