Microfluidic device to attain high spatial and temporal control of oxygen

Microfluidic devices have been successfully used to recreate in vitro biological microenvironments, including disease states. However, one constant issue for replicating microenvironments is that atmospheric oxygen concentration (21% O(2)) does not mimic physiological values (often around 5% O(2))....