Stress analysis of mandibular implant overdentures retained with one, two, or four ball attachments: A finite element study

BACKGROUND: The aim of this study is to compare stress patterns induced by ball attachments when used to retain mandibular overdentures supported by one, two, or four dental implants. MATERIALS AND METHODS: In this finite element study, three 3D models were prepared to simulate mandibular implant ov...

Popoln opis

Shranjeno v:
Bibliografske podrobnosti
izdano v:Dent Res J (Isfahan)
Main Authors: El-Zawahry, Mohamed M., Ibraheem, Eman M., Nassani, Mohammad Zakaria, Ghorab, Sahar A., El-Anwar, Mohamed I.
Format: Artigo
Jezik:Inglês
Izdano: Medknow Publications & Media Pvt Ltd 2018
Teme:
Online dostop:https://ncbi.nlm.nih.gov/pmc/articles/PMC6243807/
https://ncbi.nlm.nih.gov/pubmed/30534172