Introduction Bedside ultrasound measurement of the optic nerve sheath diameter (ONSD) is emerging as a non-invasive technique to evaluate and predict raised intracranial pressure (ICP) in both children and adults. The prognostic value of increased ONSD on brain computed tomography (CT) scan has prev...