Biomechanical evaluation of hybrid double plate osteosynthesis using a locking plate and an inverted third tubular plate for the treatment of proximal humeral fractures
BACKGROUND: Treating proximal humerus fractures can be challenging because of large metaphyseal defects that conceal anatomical landmarks. In such cases, medial cortical support with, for example, calcar screws, is mandatory. Nevertheless, varus dislocations and implant failures in patients with imp...