Hemodynamics and coil distribution with changing coil stiffness and length in intracranial aneurysms
PURPOSE: The purpose of this study was to investigate hemodynamics and coil distribution with changing coil stiffness and length using the finite element method (FEM) and computational fluid dynamics (CFD) analysis. METHODS: Basic side-wall and bifurcation type aneurysm models were used. Six types o...