A Novel Imaging Method for the Cartilaginous Eustachian Tube Lumen: Computerized Tomography During the Forced Response Test
OBJECTIVES: In vivo imaging of the open cartilaginous Eustachian tube (ET) lumen by computed tomography (CT) scan during ET function (ETF) testing to establish new methodology. METHODS: Five adults underwent unilateral ETF testing of an ear with a non-intact tympanic membrane using forced response t...