Comprehensive Calibration of Strap-Down Tri-Axis Accelerometer Unit
This paper proposes a comprehensive calibration method to improve the precision of a strap-down tri-axis accelerometer unit, in which parameters are divided into static and dynamic ones. The contribution of the manuscript is that it solves the problem of inappropriate installation and the size effec...