A carregar...
Delayed Detection of Esophageal Intubation in Anesthesia Malpractice Claims: Brief Report of a Case Series
This retrospective case series analyzed 45 malpractice claims for delayed detection of esophageal intubation from the Anesthesia Closed Claims Project. Inclusion criteria were cases from 1995–2013, after adoption of identification of CO(2) in expired gas to verify correct endotracheal tube position...
Na minha lista:
| Publicado no: | Anesth Analg |
|---|---|
| Main Authors: | , , |
| Formato: | Artigo |
| Idioma: | Inglês |
| Publicado em: |
2017
|
| Assuntos: | |
| Acesso em linha: | https://ncbi.nlm.nih.gov/pmc/articles/PMC6170013/ https://ncbi.nlm.nih.gov/pubmed/28207593 https://ncbi.nlm.nih.govhttp://dx.doi.org/10.1213/ANE.0000000000001795 |
| Tags: |
Adicionar Tag
Sem tags, seja o primeiro a adicionar uma tag!
|