A carregar...
Preload Monitoring in Bolted Connection Using Piezoelectric-Based Smart Interface
In this study, a preload monitoring method using impedance signatures obtained from a piezoelectric-based smart interface is presented for bolted girder connections. Firstly, the background theory of the piezoelectric-based smart interface and its implementation into the health monitoring of bolted...