Dislodged stent after stent reverse controlled antegrade and retrograde subintimal tracking (CART) — Is stent reverse CART a necessary tool or an unnecessary evil?

We report a case of stent reverse controlled antegrade and retrograde subintimal tracking (CART) in left anterior descending artery (LAD) chronic total occlusion. Reverse CART is the method used to make a connection between the retrograde wire and the antegrade true lumen by using a balloon to dilat...