A carregar...
Dislodged stent after stent reverse controlled antegrade and retrograde subintimal tracking (CART) — Is stent reverse CART a necessary tool or an unnecessary evil?
We report a case of stent reverse controlled antegrade and retrograde subintimal tracking (CART) in left anterior descending artery (LAD) chronic total occlusion. Reverse CART is the method used to make a connection between the retrograde wire and the antegrade true lumen by using a balloon to dilat...
Na minha lista:
| Publicado no: | J Cardiol Cases |
|---|---|
| Main Authors: | , , |
| Formato: | Artigo |
| Idioma: | Inglês |
| Publicado em: |
Japanese College of Cardiology
2017
|
| Assuntos: | |
| Acesso em linha: | https://ncbi.nlm.nih.gov/pmc/articles/PMC6149655/ https://ncbi.nlm.nih.gov/pubmed/30279836 https://ncbi.nlm.nih.govhttp://dx.doi.org/10.1016/j.jccase.2017.08.005 |