Self-inflicted and iatrogenic peripheral intravenous cannula fracture: A case report

INTRODUCTION: We present a case of broken peripheral intravenous catheter/cannula (PIVC), a well-known, underreported complication of PIVC placement. The fractured cannula could have resulted in intravascular foreign body retention, which is usually iatrogenic. PRESENTATION OF CASE: In this case, we...