New bone formation and trabecular bone microarchitecture of highly porous tantalum compared to titanium implant threads: A pilot canine study
AIM: This study evaluated new bone formation activities and trabecular bone microarchitecture within the highly porous region of Trabecular Metal™ Dental Implants (TM) and between the threads of Tapered Screw‐Vent® Dental Implants (TSV) in fresh canine extraction sockets. MATERIALS AND METHODS: Eigh...