Fixing a fractured arthrodesed hip with rapid prototype templating and minimal invasive plate osteosynthesis

CASE: We present an elderly lady with an intertrochanteric fracture of a previously fused hip. A 3D printed model of her pelvis and femur was used for implant templating before surgery. Minimal invasive fixation was performed with a spanning reversed distal femur locking plate without the need for r...