4D Microscope-Integrated OCT to Visualize Suture Depth in Strabismus Surgery

We report the use of swept-source microscope-integrated optical coherence tomography (SS-MIOCT), capable of live 4D (3D across time) intraoperative imaging, to directly visualize suture depth during lateral rectus resection. Key surgical steps visualized in this report included needle depth during p...