Advantages of wound retractor device versus rigid trocar at camera port in video-assisted thoracic surgery—a single institution experience
BACKGROUND: rigid trocars are widely adopted in video-assisted thoracic surgery (VATS), despite some disadvantages: (I) cannula strong pressure on intercostal nerve stimulating postoperative pain; (II) limited movement of thoracoscopic devices on their fulcrum when extreme acute angles with the ches...