A new ICA-based fingerprint method for the automatic removal of physiological artifacts from EEG recordings

BACKGROUND: EEG may be affected by artefacts hindering the analysis of brain signals. Data-driven methods like independent component analysis (ICA) are successful approaches to remove artefacts from the EEG. However, the ICA-based methods developed so far are often affected by limitations, such as:...