Effect of different surgical procedures on the accuracy of prediction of the plasma concentration of fentanyl: comparison between mastectomy and laparoscopic prostatectomy

BACKGROUND: The accuracy of simulation-predicted fentanyl concentration in different types of surgical procedure is not fully understood. We wished to estimate the effect of different types of surgical procedure on the accuracy of such simulations. FINDINGS: Fifty patients who had undergone elective...